• +91 9426700877
  • samratenterprise23@gmail.com
  • By Application

    Water Treatment Chemicals

    • Boiler Treatment Chemicals
    • Cooling Tower Chemicals
    • RO Chemicals
    • Waste Water Treatment Chemicals
    • Drinking Water Treatment Chemicals
    • Scale and Corrision Inhibitor

    Cleaners and Disfinfectants

    • Disinfectant and Sanitizer
    • Biocides
    • Cleaning Chemical
    • Degreasing Chemicals
    • Descaling Chemicals
    • Fumigation
    • Metal Treatment Chemicals

    Heat Transfer Fluids

    • Propylene Glycol
    • Inhibited Propylene Glycol
    • Mono Ethlene Glycol
    • Inhibited Ethylene Glycol
    • Brine Corrosion Inhibitor
    • PCM & Eutectics
    • Coolant & Coolant Additives

    Performance Chemicals

    • Acid Corrosion Inhibitor (Rodine)
    • Air Conditioning Chemicals
    • Dust Suppressant
    • Fire Retardant
    • Evaporation Retardant
    • Laundry Chemicals
  • By Industry

    Chemicals for
    Agro and F&B

    • Beverage and Brewery
    • Cold Storages
    • Dairy and Ice Cream
    • Edible Oil
    • Fishery and Meat Processing
    • Horticulture
    • Package Driniking Water
    • Pharma and Biotechnology
    • Poultry and Hatchery
    • Winery and Distillery

    Chemicals for
    Heavy Mechanical Industry

    • Iron and Steel
    • Power Station
    • Atomic Energy
    • Petrochemical and Refineries
    • Heavy Engineering Industries
    • Solar Power Plants
    • Marine and Automobile
    • Cement, Glass and Ceramics
    • Railway

    Chemicals for
    Processing Industries

    • Pulp and Paper
    • Sugar Processing
    • Leather
    • Rubber
    • Textile and Jute Processing
    • Coal Washeries and Ore Processing
    • Plastic and Woven Sacks
    • Miscellaneous Manufacturing Industries

    Chemicals for
    Institutions

    • Hospitals and Hotels
    • Housekeeping and Laundry
    • Central AC Buildings
    • Muncipality
    • HVAC and Air Conditioning
    • Thermal Energy Storage
    • Airports
  • By Brandname
  • General Chemicals
  • Home
  • About us
  • Services
    • Pharmaceutical Chemicals
    • Industrial Chemicals
    • Solvents
    • Water Treatment Chemicals
    • Cleaners & Disinfectants
    • Heat Transfer Fluids
    • Performance Chemicals
  • Inquiry
  • Contact us

Oxygen Scavenger

  1. Home
  2. Oxygen Scavenger
Ask For Price

Oxygen Scavenger

The Oxygen Scavenger is used for removing oxygen from boiler feed water straight away. The various products which we manufactured are Boiler oxygen scavenger, catalyzed sodium sulphite, hydrazine hydrate, powdered antiscalant and oxygen scavenger etc. This catalyzed scavenger converts itself to sodium bisulfate and remove oxygen instantly from boiler feed water. It is also responsible for buffering pH and reducing alkalinity of the feed water. Having precise pH value, this chemical is acknowledged for its attributes like saving power energy, minimize oxidation corrosion, removes oxygen and precise pH value. This formulation range is idyllically utilized in food & beverage, dairies, pharmaceutical, poultry and sugar industries. These chemicals also proclaims to be a metal passivator and rust convertor and proves to be a single treatment for total corrosion control in any industrial plants.



Ask For Price

Boiler Oxygen Scavenger

Samrat Industries Boiler Oxygen Scavenger is a catalyzed oxygen scavenger in liquid form based on catalyzed sodium bisulfite. It helps to instantly remove oxygen from the boiler feed water by converting itself to sodium bisulfate and also reduces alkalinity.

Key Features and Benefits

  • Catalyzed Oxygen Scavenger for instant oxygen removal
  • Minimizer or eliminates oxidation corrosion (corrosion due to presence of oxygen)
  • Concentrated powder product
  • Buffers pH
  • Imparts power saving

Application and Dosage

Samrat Industries Boiler Oxygen Scavenger should be dissolved with water in a separate tank with slow agitation and dosed continuously to the boiler feed water line after the deaerator. For every 1 ppm of dissolved oxygen, 24ppm of Samrat Industries Boiler Oxygen Scavenger should be ideally dosed. However, the dosage varies with feed water temperature, for exact dosage refers the below table:-

Feed Water Temperature Samrat Industries BOILER OXYGEN SCAVENGER (gms/ton of steam)
More than 80oC 45
60oC to 80oC 90
40oC to 60oc 180
Less than 40oC 300

Handling measures and precautions

Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage

This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing

Samrat Industries Boiler Oxygen Scavenger is available in 35kgs, 50 kgs HDPE jars and 220kgs barrels.



Ask For Price

Catalyzed Sodium Sulfite

Samrat Industries CATALYZED SODIUM SULFITE is an oxygen scavenger in powder form, based on catalyzed sodium sulfite. It helps to instantly remove oxygen from the boiler feed water by converting itself to sodium sulfate.

Key Features and Benefits

  • Catalyzed Oxygen Scavenger for instant oxygen removal
  • Minimize or eliminates oxidation corrosion (corrosion due to presence of oxygen)
  • Concentrated powder product
  • Buffers pH
  • Imparts power saving

Application and Dosage

Samrat Industries CATALYZED SODIUM SULFITE should be dissolved with water in a separate tank with slow agitation and dosed continuously to the boiler feed water line after the deaerator.

For every 1 ppm of dissolved oxygen, 8-10ppm of Catalysed Sodium Sulphite should be ideally dosed. However, the dosage varies with feed water temperature, for exact dosage refers the below table:-

Feed Water Temperature S100 (gms/ton of steam)
More than 80oC 15
60oC to 80oC 30
40oC to 60oc 60
Less than 40oC 100

Handling measures and precautions

Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage

This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing

Samrat Industries CATALYZED SODIUM SULFITE is available in 50kgs air-tight open mouth HDPE jars.



Ask For Price

Hydrazine Hydrate

Hydrazine hydrate and its derivatives play a significant role in various applications that contribute to ensure comfort, safety and healthcare in our everyday life.

Here we discuss the use of Hydrazine Hydrate as Oxygen Scavenger in Boiler water treatment.

Hydrazine Hydrate is a clear colorless liquid. It generally comprises of a 80% assay product, that is used for removing dissolved oxygen in boiler treatment.

Key Features and Benefits

  • Removes dissolved oxygen
  • Prevents oxidation corrosion
  • Causes mild steel passivation
  • Does not add to TDS of boiler water
  • Completely volatile

Application and Dosage

Hydrazine Hydrate is dosed in the aerator of the boiler at the recommended dosage that is prescribed after analysis of dissolved oxygen in the water and other system parameters.

Please refer your CSL representative to recommend exact dosage.

Handling measures and precautions

Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage

This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing

This product is available in 200kgs HDPE drums and 50kgs jars.



Ask For Price

Hydrazine Hydrate with Catalyst

Samrat Industries Hydrazine Hydrate With Catalyst is a very effective oxygen scavanger based on a volatile liquid formulation of hydrazine and catalyst. It is used to remove the even the last traces of dissolved oxygen from the boiler feed water by the following equation:-

O2+ N2H4 2H2O + N2 Oxygen + Hydrazine Water + Nitrogen Gas

The catalyst in the product helps to increase the rate of the above reaction and ensures complete removal of dissolved oxygen in boiler feed water in lesser time.

Samrat Industries Hydrazine Hydrate With Catalyst also prevents corrosion by forming a protective passive film on metal and by boosting the pH in condensate line.

Key Features and Benefits
  • Catalyzed Oxygen Scavenger for instant oxygen removal
  • Does not add to the TDS of boiler water, since the product is volatile
  • Minimizes oxidation corrosion (corrosion due to presence of oxygen)
  • Catalyst in the product reduces the requirement of hydrazine for oxygen removal
  • Prevents corrosion by forming a passive protective film over the metal surface
  • Increases the condensate pH and minimizes corrosion of steam lines

Application and Dosage
Samrat Industries Hydrazine Hydrate With Catalyst is dosed at the rate of 5ppm for every ppm of dissolved oxygen from boiler feed water. It is recommended to maintain an excess dosage of 1.1 to 1.2 times the desired dosage as reserve for compensating the variation in oxygen content.

Please refer to your CSL service engineer for exact product dosage and dosing practice.

Handling measures and precautions
Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage
This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing
Samrat Industries Hydrazine Hydrate With Catalyst is available in 35kgs HDPE jars and 200kgs barrels.




Ask For Price

Powder Antiscalant and Oxygen Scavenger

Samrat Industries Powder Antiscalant and Oxygen Scavenger is a blend of powder antiscalant and catalyzed oxygen scavenger, designed for boiler water treatment used in coil type boilers. The antiscalant inhibits deposition of calcium and iron scales on coils.

Key Features and Benefits
  • Catalyzed Oxygen Scavenger for instant oxygen removal
  • Minimizer or eliminates oxidation corrosion (corrosion due to presence of oxygen)
  • Concentrated powder product
  • Prevents scaling and thus overheating of coil
  • Imparts power saving

Application and Dosage
Samrat Industries POWDER ANTISCALANT AND OXYGEN SCAVENGER is dosed at the rate of 15 to 100gms per ton of steam generation, depending upon the feed water temperature and type of boiler system.

Please refer to your CSL service engineer for exact product dosage.

Handling measures and precautions
Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage
This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing
Samrat Industries Powder Antiscalant and Oxygen Scavenger is available in 25kgs air-tight open mouth HDPE jars.



Ask For Price

DEHA

Samrat Industries Deha is a volatile catalyzed oxygen scavenger cum condensate line treatment chemical. It is based on DEHA catalyzed with hydroquinones.

Samrat Industries Deha reacts with oxygen to form acetates, nitrogen and water. It passivates the metal surfaces in the boiler, and then passes out of the boiler with the steam, and act as a metal passivating agent in the return line system.

Key Features and Benefits
  • Completely organic compound
  • Volatile - Does not add TDS to blow down water
  • Metal passivator and rust converter
  • Effective condensate line treatment and pH booster
  • Non-toxic and more safe than hydrazine and carbohydrazide based chemicals
  • Compatible with other treatment chemicals
  • Returns to the feed line with the condensate return so passivates total system
  • High rate of reaction with oxygen compared with other oxygen scavengers
  • It offers a vapor-liquid distribution ratio of 1.3 and thus distributes all along the condensate circuit, ensuring a total control of corrosion
  • Single treatment for total corrosion control in boiler

Application and Dosage
Samrat Industries Deha is fed neat (undiluted) continuously to the boiler feed water depending upon the dissolved oxygen content, temperature and pressure of boiler. Theoretically the dosage is 1.3 parts active ingredient for every part of oxygen, but in application, a dosage of 3ppm active for every ppm of O2 is recommended.

Handling measures and precautions
Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

Storage
This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight. Please refer Technical Data Sheet, Label and MSDS for more details and shelf life.

Packing
Samrat Industries DEHA is available in the following pack size of 35/200kgs HDPE jars and barrels.



Water Treatment Chemicals

  • Boiler Treatment Chemicals
  • Cooling Tower Chemicals
  • RO Chemicals
  • Waste Water Treatment Chemicals
  • Drinking Water Treatment Chemicals
  • Scale and Corrision Inhibitor

Cleaners and Disfinfectants

  • Disinfectant and Sanitizer
  • Biocides
  • Cleaning Chemical
  • Degreasing Chemicals
  • Descaling Chemicals
  • Fumigation
  • Metal Treatment Chemicals

Heat Transfer Fluids

  • Propylene Glycol
  • Inhibited Propylene Glycol
  • Mono Ethlene Glycol
  • Inhibited Ethylene Glycol
  • Brine Corrosion Inhibitor
  • PCM & Eutectics
  • Coolant & Coolant Additives

Performance Chemicals

  • Acid Corrosion Inhibitor (Rodine)
  • Air Conditioning Chemicals
  • Dust Suppressant
  • Fire Retardant
  • Evaporation Retardant
  • Laundry Chemicals

Our Products

  • Pharmaceutical Chemicals
  • Industrial Chemicals
  • Solvents
  • Water Treatment Chemicals
  • Cleaners & Disinfectants
  • Heat Transfer Fluids
  • Performance Chemicals

Menu

  • Home
  • About us
  • Our Products
  • Inquiry
  • Contact us

Location Map

Contact us

  • Address: Plot No. 115, Shivshakti Industrial Estate, Nr. Kotarpur Water Project, Opp-Nobel Nagar Naroda Ahmedabad-382340
  • Mobile No. +91 94267 00877
  • E-mail samratenterprise23@gmail.com
Samrat Industries © Copyright 2017. Design By: Krishna Techno